Burners and Boilers -
Boilers
|
FUL15 Medical Incinerator| medical waste incinerator |
|
|
Use: This product is mainly suitable for solid medical service trash (including pollutants), waste plastic and rubber and so on will decompose under high temperature into organic compounds. Characteristic: 1, uses advanced closed high temperature instantaneous combustion system, ensure high thermal efficiency. 2, Total combustion, burning out medical reject food debris, plastic and organic matter etc. 3, smokeless, odourless and non- polluting. 4, Large volume 70cm door size for bulk loading. 5, Thrre times the volume compared to earlier units of the same type. 6th, Double burner combustion technology reduces the ash component. 7th, Special fire-proof ceramic material, ensures safety and reliability.
|
| Combustion technical parameters: Model | Combustion type number | Fuel hold-up | Control mode | Power source | Air blower power (KW) | | FSL-50 | OM-2 OM-3 | 25-30 | ON-OFF | 380V 50HZ | 0.15+0.25+3.3 | | FSL-100 | OM-3 LT-81 | 30-60 | ON-OFF | 380V 50HZ | 0.25+1.1+3.3 |
Bed number and reject quantity:
| Bed number | Total displacement (Per day) | Infectious reject (Per day) | | 50 | 50-75 Kg | 15-25 Kg | | 100 | 100-150 Kg | 25-50 Kg | | 200 | 200-300 Kg | 50-70 Kg | | 300 | 300-450 Kg | 70-130 Kg | | 400 | 400-600 Kg | 120-170 Kg | | 500 | 500-750 Kg | 150-230 Kg |
|
|