|
Burners and Boilers -
Burners
|
AG Series Gas Burners   | Small flame starter that goes to full burning once efficient burning is in process. The full flow then starts so that a more efficient flame is used.  For fitting in small boilers, drying and heating equipments, cooking range used in the catering trade and steam cupboards. | | SPECIFICATIONS | | | | | | | | | ITEM | MAX | | GAS | POWER | SUPPLY | CONTROL | MOTOR | SAFETY | | MODEL | OUTPUT cal/hr | GAS | PRESSURE | V | F | SYSTEM | KW | DEVICES | | AG-5S | 50000 | | | 100/220 | 1 | | 0.04 | | | AG-10S | 100000 | | | | | | 0.15 | | | AG-15S | 150000 | | | 100/220/220 | 1/1/3 | | 0.25 | AIR | | AG-25S | 250000 | | | | | ON-OFF | 0.4 | PRESSURE | | AG-30S | 300000 | | | | | | 0.4 | SWITCH | | AG-40S | 400000 | NATURAL | NATURAL | | | | 0.75 | AND FLAME | | AG-45S | 450000 | OR | 200 | 220/380 | 3 | | 0.75 | ROD | | AG-60S | 600000 | LPG | | | | ON-OFF/2 STAGE | 1.0 | | | AGP-80S | 800000 | | LPG | | | | 1.5 | AIR | | AGP-100S | 1000000 | | 280 | | | | 1.5 | PRESSURE | | AGP-150S | 1500000 | | | | | PROPORTIONAL | 2.2 | SWITCH | | AGP-200S | 2000000 | | | | | | 3.7 | AND FLAME | | AGP-250S | 2500000 | | | | | | 5.5 | DETECTOR | | AGP-300S | 3000000 | | | | | | 7.5 | |   | 1. FAN 2. MAIN BURNER 3. PILOT BURNER 4. MAIN TEST COCK 5. GAS FLOW RATE ADJUSTING VALVE 6. MAIN SHUT-OFF VALVE 7. PILOT TEST COCK 8. PILOT SOLENOID VALVE 9. PILOT GOVERNER 10. IGNITION TRANSFORMER 11. CONTROL MOTOER 12. AIR PRESSURE SWITCH 13. FLAME DETECTOR 14. GAS PRESSURE SWITCH (LOW) (OPTIONAL) 15. GAS PRESSURE GUAGE (OPTIONAL) | | MODEL | A | B | C | D | E | F | G | D-I | DI | J | K | | AG-5S | 250 | 270 | 270 | 275 | 115 | 100 | 101 | 200 | 180 | - | 4-f10 | | AG-10S | 270 | 277 | 275 | 290 | 120 | 100 | 114 | 200 | 180 | - | 4-f10 | | AG-15S | 362 | 293 | 360 | 365 | 135 | 100 | 140 | 270 | 240 | - | 8-f12 | | AG-25S | 397 | 293 | 410 | 415 | 135 | 100 | 160 | 270 | 240 | - | 8-f12 | | AG-30S | 425 | 305 | 440 | 470 | 135 | 120 | 180 | 270 | 240 | - | 8-f12 | | AG-40S | 460 | 305 | 480 | 505 | 135 | 120 | 180 | 270 | 240 | - | 8-f12 | | AG-45S | 460 | 305 | 480 | 505 | 135 | 120 | 180 | 270 | 240 | - | 8-f12 | | AG-60S | 505 | 435 | 540 | 540 | 155 | 120 | 216 | 340 | 310 | - | 8-f12 | | AGP-80S | 576 | 450 | 570 | 640 | 175 | 150 | 240 | 390 | 350 | 240 | 12-f12 | | AGP-100S | 576 | 460 | 570 | 650 | 182 | 150 | 260 | 400 | 364 | 240 | 12-f12 | | AGP-150S | 625 | 490 | 580 | 710 | 225 | 180 | 290 | 450 | 410 | 240 | 12-f13 | | AGP-200S | 676 | 510 | 600 | 760 | 245 | 180 | 330 | 490 | 450 | 260 | 12-f13 | | AGP-250S | 910 | 525 | 640 | 1120 | 260 | 200 | 360 | 520 | 480 | 280 | 12-f13 | | AGP-300S | 950 | 550 | 660 | 1150 | 290 | 200 | 410 | 580 | 544 | 300 | 12-f13 | | Note dimensional values above are all standard specifications. | | | | | | If you need special specifications please ask us for a separate drawing | | | | | Piping dimensions vary according to the type of gas | | | | | | 
|