JTCLASSBLU 15

GTranslate

Advertisement


The Internet Topsites
New Zealand Top Sites
AG Series Gas Burners PDF Print E-mail
Burners and Boilers - Burners

AG Series Gas Burners

 

 

Small flame starter that goes to full burning once efficient burning is in process. The full flow then starts so that a more efficient flame is used.

 
For fitting in small boilers, drying and heating equipments, cooking range used in the catering trade and steam cupboards.

SPECIFICATIONS

 

 

 

 

 

 

 

ITEM

MAX

 

GAS

POWER

SUPPLY

CONTROL

MOTOR

SAFETY

MODEL

OUTPUT cal/hr

GAS

PRESSURE

V

F

SYSTEM

KW

DEVICES

AG-5S

50000

 

 

100/220

1

 

0.04

 

AG-10S

100000

 

 

 

 

 

0.15

 

AG-15S

150000

 

 

100/220/220

1/1/3

 

0.25

AIR

AG-25S

250000

 

 

 

 

ON-OFF

0.4

PRESSURE

AG-30S

300000

 

 

 

 

 

0.4

SWITCH

AG-40S

400000

NATURAL

NATURAL

 

 

 

0.75

AND FLAME

AG-45S

450000

OR

200

220/380

3

 

0.75

ROD

AG-60S

600000

LPG

 

 

 

ON-OFF/2 STAGE

1.0

 

AGP-80S

800000

 

LPG

 

 

 

1.5

AIR

AGP-100S

1000000

 

280

 

 

 

1.5

PRESSURE

AGP-150S

1500000

 

 

 

 

PROPORTIONAL

2.2

SWITCH

AGP-200S

2000000

 

 

 

 

 

3.7

AND FLAME

AGP-250S

2500000

 

 

 

 

 

5.5

DETECTOR

AGP-300S

3000000

 

 

 

 

 

7.5

 

 

 

1. FAN

2. MAIN BURNER 

3. PILOT BURNER

4. MAIN TEST COCK

5. GAS FLOW RATE ADJUSTING VALVE

6. MAIN SHUT-OFF VALVE

7. PILOT TEST COCK

8. PILOT SOLENOID VALVE

9. PILOT GOVERNER

10.  IGNITION TRANSFORMER

11.  CONTROL MOTOER

12. AIR PRESSURE SWITCH

13.  FLAME DETECTOR

14.  GAS PRESSURE SWITCH (LOW) (OPTIONAL)

15.  GAS PRESSURE GUAGE (OPTIONAL)

MODEL

A

B

C

D

E

F

G

D-I

DI

J

K

AG-5S

250

270

270

275

115

100

101

200

180

-

4-f10

AG-10S

270

277

275

290

120

100

114

200

180

-

4-f10

AG-15S

362

293

360

365

135

100

140

270

240

-

8-f12

AG-25S

397

293

410

415

135

100

160

270

240

-

8-f12

AG-30S

425

305

440

470

135

120

180

270

240

-

8-f12

AG-40S

460

305

480

505

135

120

180

270

240

-

8-f12

AG-45S

460

305

480

505

135

120

180

270

240

-

8-f12

AG-60S

505

435

540

540

155

120

216

340

310

-

8-f12

AGP-80S

576

450

570

640

175

150

240

390

350

240

12-f12

AGP-100S

576

460

570

650

182

150

260

400

364

240

12-f12

AGP-150S

625

490

580

710

225

180

290

450

410

240

12-f13

AGP-200S

676

510

600

760

245

180

330

490

450

260

12-f13

AGP-250S

910

525

640

1120

260

200

360

520

480

280

12-f13

AGP-300S

950

550

660

1150

290

200

410

580

544

300

12-f13

Note dimensional values above are all standard specifications.

 

 

 

 

If you need special specifications please ask us for a separate drawing

 

 

 

Piping dimensions vary according to the type of gas